Skip to main content

17.05.180 Stockpiling and temporary fills.

17.05.150 Dust control.

All graded surfaces and materials, whether filled, excavated, transported or stockpiled, shall be wetted, protected or contained in such a manner to prevent dust or spillage upon adjacent property or streets. Equipment, material and roadways on the site shall be used in such manner or so treated as to prevent excessive dust conditions. (Ord. 16432 § 6(2), 3-10-92. Code 1995 § 66-122.)

17.05.160 Slope of cut surfaces.

The slope of cut surfaces shall be no steeper than is safe for the intended use and shall be no steeper than three horizontal to one vertical unless approved by the department of public works. (Ord. 16432 § 6(3), 3-10-92. Code 1995 § 66-123.)

17.05.170 Fills.

(a) Fill Location. Fill slopes shall not be constructed on natural slopes steeper than three to one unless approved by the department of public works.
(b) Preparation of Ground. The ground surface shall be prepared to receive fill by removing vegetation, noncomplying fill, topsoil and other unsuitable materials and scarifying to provide a bond with the new fill.
(c) Fill Material. Detrimental amounts of organic material shall not be permitted in fills. Except as permitted, no rock or similar irreducible material with a maximum dimension greater than 12 inches shall be buried or placed in fills. The development coordination office may permit placement of larger rock when a soils engineer properly devises a method of placement, continuously inspects its placement and approves the fill stability.
(d) Compaction. All fills shall be compacted to a minimum of 90 percent of maximum density tested by the Standard Proctor method unless specifically exempted from this requirement by the department of public works.
(e) Slope. The slope of fill surfaces shall be no steeper than is safe for the intended use. Fill slopes shall be no steeper than three horizontal to one vertical unless approved by the department of public works. (Ord. 16432 § 6(4), 3-10-92. Code 1995 § 66-124.)

17.05.180 Stockpiling and temporary fills.

The minimum standards set out in TMC 17.05.170 shall also apply to stockpiling and temporary fills with the exception that subsections (b) through (d) thereof may be waived by the director of public works upon proper written justification. (Ord. 16432 § 6(5), 3-10-92. Code 1995 § 66-125.)